Gwh/yr

Energy Generation

0.1MW

Installed Capacity

Salient Features

Hydrology ( Intake )

Catchment Area 136.5 km 2
Design Discharge 7.3 m 3 /s
Maximum Net Head 48.27 m
Maximum Gross Head 51.48 m

Waterways

Headrace Tunnel-Length 1120 m
Penstock- Length 126 m
Penstock-Diameter 1.8 m
Tailrace Canal Length 236.5 m

Turbine

Type Horizontal axis Francis turbine
Rated Output 2 X 12.5 MW

Generators

Rated Capacity 17.6 MVA
Type Synchronous, Three Phase
check-mark

Application for Survey License

check-mark

Survey License Approved

check-mark

Application for Generation License

check-mark

Under Construction

check-mark

Live

Location